Wire a Light Switch From a Receptacle

Wire a new switch to control an existing receptacle. A table lamp plugged into the switched outlet of a duplex receptacle will allow easy lighting of the room from a wall switch. This is an alternative to waving your arms while wandering about in a dark room trying to find a pull chain.

Steps

Preparing for Wiring

  1. Study the diagram below, photos and step by step procedure before attempting. Do not attempt unless you have a complete understanding of the job.

  2. Shut off power to the circuit.
  3. Test the circuit with a tester or lamp prior to working to be sure power has been removed.
  4. Remove the wall plate from the receptacle and save the screws for reuse.
  5. Unscrew the receptacle from the box and save screws for reuse.
  6. Pull the receptacle gently but firmly away from the box.
  7. Identify each terminal screw with a number written on masking tape, affixed close by. A booklet of adhesive numbers (like that in the photo) is great aid for a job like this.

  8. Mark the silver or white terminals with even numbers 2 and 4; the green safety ground terminal (if provided) should be marked 5. The gold terminals on the other side should be marked with odd numbers 1 and 3. Be sure to mark all terminals even if no wires are connected to them.



  9. Label each wire with the terminal number to which it is connected. Write the terminal number on a piece of masking tape and wrap around the wire's insulation. A wire under a gold screw 1 should have a 1 tag on it, while a wire under white screw 2 should have a 2 on it. The bare or green ground wire connected under terminal 5 would have a 5 tag, as in the above photos.
  10. Inspect the side of the receptacle with gold screws and locate the metal tab that connects the two square gold pads into which the gold screws are threaded. It can usually be found on the side - but close to the front of the receptacle. If it is already removed, STOP and reassemble. This installation is not covered in this wiki at this time.
  11. Disconnect all the wires from the receptacle by loosening the terminal screws. It is not required to remove the screws. The screws can not be removed unless forced.
  12. Install an old work switchbox and run "2 wire" (two conductors AND ground conductor) Romex ® type cable of the same size wire serving the receptacle, between this old work  switchbox and the receptacle (most likely 14 or 12 gauge). Do not cut cable until sure it is of sufficient length and even then leave {{safesubst:#invoke:convert|convert}} extra before making the cut.
  13. Remove {{safesubst:#invoke:convert|convert}} of the cable jacket from both ends and pass the cable into each of the boxes through the opening until 1/2 to not more than {{safesubst:#invoke:convert|convert}} of the jacket is visible inside.
  14. Strip the new white and new black wires 1/2 to 3/4 of an inch.
  15. Identify the new white wire with a 13 tag.
  16. Identify the new black wire with a 7 tag.

Wiring the Receptacle

  1. Remove the tab that connects the two square gold pads (into which the gold screws are threaded) by grabbing it with needle nose pliers and working it back and forth until it breaks free completely. Do not remove the tab on the silver or white side of the receptacle.



  2. Combine all the ground wires AND a spare piece of bare wire (or insulated wire stripped completely of insulation) and cut to {{safesubst:#invoke:convert|convert}}, together under a properly sized wirenut.
  3. Form a hook at the loose end of the bare wire above and secure under terminal 5. Gently fold the ground wires and wirenut as far back into the box as possible.
  4. Gather all the wires with a 2 and 4 tag (most likely white wires). If there is more than one wire, combine them AND a spare piece of white insulated wire cut to {{safesubst:#invoke:convert|convert}} and stripped 1/2 - 3/4 of an inch at the end, together under a properly sized wirenut. If there is only one wire with a 2 or 4 tag, assume it is white and go to the next step.
  5. Form a hook at the loose end of the white wire and secure under terminal 2 or 4, it does not matter which is used. Gently fold the excess wire and wirenut to the back of the box.

  6. Gather all the wires with a 1 and 3 tag (most likely black and/or red wires). Be sure to include the new white wire with a 13 tag on it (the number 13 was chosen for connection with the other 1's and 3's). Combine them AND a spare piece of black insulated wire cut to {{safesubst:#invoke:convert|convert}} and stripped 1/2 - 3/4 of an inch at the ends, together under a properly sized wirenut.
  7. Form a hook at the loose end of the short black wire added above and secure under terminal 1 or 3. Tag this wire with the same number as the terminal connected (1 or 3). This connected terminal is now the unswitched terminal of the receptacle, and will always be on. Gently fold the excess wire and wirenut to the back of the box.
  8. Cover or replace the tag for the unused gold terminal screw with a new 7 tag.
  9. Form a hook at the end of the new black wire with the 7 tag and tighten under the 7 terminal on the receptacle. Gently fold the excess wire to the back of the box. This is now the switched terminal of the receptacle and will be on only when the switch is set to on. If the 7 terminal is the bottom - the switched outlet will be on the bottom, conversely, if 7 is the top terminal, the switched outlet will be on the top.



  10. Secure the receptacle to the box.
  11. Secure the wall plate to the receptacle.
  12. Plug a lamp into the switched outlet of the receptacle.

Wiring the Switch

  1. Strip both of the Romex conductors 1/2 to 3/4 of an inch.
  2. Form a hook at the end of all three conductors.
  3. Connect the bare wire of the Romex cable that connects to the receptacle described above under the green screw (if provided) of the switch. If there are other ground wires in this box, the new wire should be connected to them with a wirenut and short bare wire(s) extended to each switch and other device(s) in the box. Gently fold the excess wire to the back of the box.
  4. Connect the black wire of the Romex cable that connects to the receptacle described above under either gold screw of the switch. Gently fold the excess wire to the back of the box.
  5. Connect the white wire of the Romex cable that connects to the receptacle described above under the remaining unused gold screw of the switch.
  6. Orient the switch. If the switch has "ON" and "OFF" indicated on the handle, make sure it is positioned so it can be read, and not upside-down ("FFO" and "NO").
  7. Gently fold the excess wire to the back of the box.
  8. Secure the switch to the box.
  9. Secure the wall plate to the switch.
  10. Restore power to the circuit.
  11. Test the installation by operating the switch. Make sure that the switch on the lamp is set to "on" if it doesn't work at first.



Tips

  • All ground wires should be connected together whenever they appear in boxes. Use as many pigtails as there are ground terminals to extend the ground to each device's ground terminal as described in the previous step.
  • If unable to install the plug or switch all the way into the box, the conductors and wirenuts may be in the way. Rearrange the wires and wirenuts so they lay as flat as possible against the back or sides of the box, and try again. Do not force the device into the box by the screws, as damage to the insulation may result.
  • Hooks formed at the end of the wire for placement under screw terminals are to be wrapped clockwise around a screw.
  • Screw terminals cannot have more than a single wire connected. To connect more than one wire to a terminal a pigtail is used. A pigtail is an {{safesubst:#invoke:convert|convert}} long piece of wire that is the same size and has the same color insulation as those wires that need to be connected, and is stripped on both ends. Combine all the wires that need to be connected to the terminal with an end of the pigtail in a wirenut. Form a hook at the other end of the pigtail to connect to the screw terminal. Never use green or bare pigtails unless they are for ground, and never used white or gray pigtails unless they are neutral.
  • Plastic electrical boxes are assumed. If metal boxes are used, an additional pigtail should be installed to firmly connect the ground wires to a ground screw installed into the box solely for this purpose.
  • The outer jacket of Romex cable should not extend more than an inch into a box.
  • Strip the jacket of the Romex cable to expose {{safesubst:#invoke:convert|convert}} of the wires. It is important to have enough wire with which to work when devices (switches, plugs, etc) are pulled from the box. Devices that can only be pulled out of the box a couple of inches or so are extremely difficult to work on. The wires should be shortened only when the device (when installed) crushes the wires and insulation.

Things You'll Need

  • Screw drivers - Phillips & straight blade types
  • Lineman's Pliers
  • Needle Nose Pliers (to remove tab between gold screw terminals)
  • Wirenuts
  • 14-2 or 12-2 Romex (must be sized the same as the outlet conductors)
    • Realize that Romex ® is a brand name of NM (Non-Metallic shield) type cable (like Formica was to laminate). If Romex is not understood, try referring to it as NM type cable or "building wire".
  • Single pole switch
  • Old work switchbox
  • Masking tape (or booklet of adhesive numbers)
  • Pen, pencil or marker